FMF Timing for STDS244 Parts version: | author: | mod date: | changes made: V1.0 R. Munden 99 JUL 02 Initial release 1ns STDS244 IDT74FST163244PAIDT Data Sheet February 1997 IDT74FST163244PFIDT Data Sheet February 1997 IDT74FST163244PVIDT Data Sheet February 1997 The values listed are for VCC=5V, CL=50pF, Ta=-40 to +85 Celsius Typical values are derived (DELAY (ABSOLUTE (IOPATH A B (0.1:0.2:0.25) (0.1:0.2:0.25)) (IOPATH OENeg A (1.5:4.0:6.5) (1.5:4.0:7.0)) )) SN74CBT16244DGGTexas Instruments SCDS031E-Revised March 1998 SN74CBT16244DGVTexas Instruments SCDS031E-Revised March 1998 SN74CBT16244DLTexas Instruments SCDS031E-Revised March 1998 The values listed are for VCC=5V, CL=50pF, Ta=-40 to +85 Celsius Typical values are derived (DELAY (ABSOLUTE (IOPATH A B (0.1:0.2:0.25) (0.1:0.2:0.25)) (IOPATH OENeg A (1.0:3.0:5.1) (1.0:3.0:5.4)) ))