FMF Timing for STDS16210 Parts version: | author: | mod date: | changes made: V1.0 R. Munden 99 JUL 02 Initial release V1.1 R. Munden 03 JAN 24 added 5 new part numbers 1ns STDS16210 SN74CBT16210DGGTexas Instruments SCDS033C-Revised May 1998 SN74CBT16210DGVTexas Instruments SCDS033C-Revised May 1998 SN74CBT16210DLTexas Instruments SCDS033C-Revised May 1998 The values listed are for VCC=5V, CL=50pF, Ta=-40 to +85 Celsius Typical values are derived (DELAY (ABSOLUTE (IOPATH A B (0.1:0.2:0.25) (0.1:0.2:0.25)) (IOPATH OENeg A (3.3:6.6:8.6) (2.8:5.6:7.9)) )) CBTD16210DGGPhilips Semiconductors 853-2221 24787 2000 Oct 12 CBTD16210DLPhilips Semiconductors 853-2221 24787 2000 Oct 12 The values listed are for VCC=5V, CL=50pF, Ta=-40 to +85 Celsius Typical values are derived (DELAY (ABSOLUTE (IOPATH A B (0.1:0.2:0.25) (0.1:0.2:0.25)) (IOPATH OENeg A (1.5:3.5:6.0) (1.5:6.0:9.0)) )) SN74CBTD16210DGGTexas Instruments SCDS049H-Revised July 2002 SN74CBTD16210DGVTexas Instruments SCDS049H-Revised July 2002 SN74CBTD16210DLTexas Instruments SCDS049H-Revised July 2002 The values listed are for VCC=5V, CL=50pF, Ta=-40 to +85 Celsius Typical values are derived (DELAY (ABSOLUTE (IOPATH A B (0.1:0.2:0.25) (0.1:0.2:0.25)) (IOPATH OENeg A (1.5:6.8:9.8) (1.5:6.5:8.9)) ))