FMF Timing for std12 Parts version: | author: | mod date: | changes made: V1.0 R. Munden 00 Nov 24 Initial release 1ns std12 SN5412JTexas Instruments SDLS040-Revised March 1988 SN5412WTexas Instruments SDLS040-Revised March 1988 SN7412NTexas Instruments SDLS040-Revised March 1988 The Values listed are for VCC=5V, CL=15pF, Ta=25C Minimum values are derived (DELAY (ABSOLUTE (IOPATH A YNeg (25:35:45) (4:8:15)) )) SN54LS12JTexas Instruments SDLS040-Revised March 1988 SN54LS12WTexas Instruments SDLS040-Revised March 1988 SN54LS12FKTexas Instruments SDLS040-Revised March 1988 SN74LS12DTexas Instruments SDLS040-Revised March 1988 SN74LS12NTexas Instruments SDLS040-Revised March 1988 The Values listed are for VCC=5V, CL=15pF, Ta=25C Minimum values are derived (DELAY (ABSOLUTE (IOPATH A YNeg (10:17:32) (8:15:28)) ))