FMF Timing for sy89832u Part version: | author: | mod date: | changes made: V1.0 D.Popovic 06 Mar 10 Initial release V1.1 R. Munden 08 Sep 30 Corrected port names 1ns sy89832u SY89832UMIMicrel, Inc., September 2005 SY89832UMITRMicrel, Inc., September 2005 SY89832UMGMicrel, Inc., September 2005 SY89832UMGTRMicrel, Inc., September 2005 The values listed are for Vcc=+2.5V+/-5% or +3.3V+/-10%, Rl = 100 Ohm,VIn less then 400 mV Ta=-40 to +85C (DELAY (ABSOLUTE (COND Vin==TRUE (IOPATH INput Q0 (0.37:0.47:0.57)(0.37:0.47:0.57))) (COND Vin==FALSE (IOPATH INput Q0 (0.3:0.41:0.50)(0.3:0.41:0.50))) )) (TIMINGCHECK (SETUP EN INput (0.3)) (HOLD EN INput (0.3)) (PERIOD INput (0.4)) )