FMF Timing for ECLPS150 Parts version: | author: | mod date: | changes made: V1.0 G. De Smet 96 SEP 03 Initial release V1.1 G. De Smet 97 JUL 31 Changed MIN for MAX for all except: IOPATH V1.2 fixftm 97 DEC 06 Modified to work with mk_sdf 1.15 V1.3 R. Munden 99 APR 29 Made timing checks worst case only 1ns ECLPS150 MC100E150FNMOTOROLA High Performance ECL Data ECLinPS and ECLinPS Lite May 1995 MC10E150FNMOTOROLA High Performance ECL Data ECLinPS and ECLinPS Lite May 1995 SY100E150JSynergy Product Data Book 1994 SY10E150JSynergy Product Data Book 1994 The Values listed are for Ta=+25 Celsius The Values listed for SETUP Max, HOLD Max, RECOVERY Max, WIDTH Typ_Max, are derived (DELAY (ABSOLUTE (IOPATH MR Q (.450:.625:.750) (.450:.625:.750)) (IOPATH D Q (.250:.375:.550) (.250:.375:.550)) (IOPATH LEN1 Q (.375:.500:.700)(.375:.500:.700)) )) (TIMINGCHECK (SETUP D LEN1 (.200)) (HOLD D LEN1 (.200)) (RECOVERY MR LEN1 (.750)) (WIDTH (posedge MR) (.400)) )