FMF Timing for ECLPS143 Parts version: | author: | mod date: | changes made: V1.0 G. De Smet 97 MAY 15 Initial release V1.1 G. De Smet 97 JUL 31 Changed MIN for MAX for all except: IOPATH V1.2 fixftm 97 DEC 06 Modified to work with mk_sdf 1.15 V1.3 R. Munden 98 APR 04 Modified for NTC 1ns ECLPS143 MC100E143FNMOTOROLA High Performance ECL Data ECLinPS and ECLinPS Lite May 1995 MC10E143FNMOTOROLA High Performance ECL Data ECLinPS and ECLinPS Lite May 1995 SY100E143JSynergy Product Data Book 1994 SY10E143JSynergy Product Data Book 1994 The Values listed are for Ta=+25 Celsius The Values listed for SETUP Max, HOLD Max, RECOVERY Max, WIDTH Typ_Max, PERIOD Max, are derived (DELAY (ABSOLUTE (IOPATH CLK1 Q (.600:.800:1.000)(.600:.800:1.000)) (IOPATH MR Q (.600:.800:1.000)(.600:.800:1.000)) )) (TIMINGCHECK (SETUP D CLK1 (-.250:-.100:.050)) (SETUP D CLK2 (-.250:-.100:.050)) (SETUP SEL CLK1 (0.0:.150:.300)) (HOLD D CLK1 (-.100:.100:.300)) (HOLD D CLK2 (-.100:.100:.300)) (HOLD SEL CLK1 (-.225:-.150:.075)) (RECOVERY MR CLK1 (.500:.700:.900)) (WIDTH (posedge MR) (.400:.400:.400)) (WIDTH (posedge CLK1) (.400:.400:.400)) (WIDTH (negedge CLK1) (.400:.400:.400)) (PERIOD (posedge CLK1) (.909:1.111:1.429)) )