FMF Timing for ECLPS142 Parts version: | author: | mod date: | changes made: V1.0 G. De Smet 96 MAY 15 Initial release V1.1 G. De Smet 97 JUL 31 Changed MIN for MAX for all except: IOPATH V1.2 fixftm 97 DEC 06 Modified to work with mk_sdf 1.15 V1.3 R. Munden 98 APR 04 Added CLK2 params for NTC 1ns ECLPS142 MC100E142FNMOTOROLA High Performance ECL Data ECLinPS and ECLinPS Lite May 1995 MC10E142FNMOTOROLA High Performance ECL Data ECLinPS and ECLinPS Lite May 1995 SY100E142JSynergy Product Data Book 1994 SY10E142JSynergy Product Data Book 1994 The Values listed are for Ta=+25 Celsius The Values listed for SETUP Max, HOLD Max, RECOVERY Max, WIDTH Typ_Max, PERIOD Max, are derived (DELAY (ABSOLUTE (IOPATH CLK1 Q0 (.600:.800:1.0) (.600:.800:1.0)) (IOPATH MR Q0 (.600:.800:1.0) (.600:.800:1.0)) )) (TIMINGCHECK (SETUP D0 CLK1 (-.250:-.100:.050)) (SETUP D0 CLK2 (-.250:-.100:.050)) (SETUP SEL CLK1 (0.0:.150:.300)) (HOLD D0 CLK1 (-.100:.100:.300)) (HOLD D0 CLK2 (-.100:.100:.300)) (HOLD SEL CLK1 (-.375:-.150:.75)) (RECOVERY MR CLK1 (.500:.700:.900)) (WIDTH (posedge MR) (.400:.400:.400)) (WIDTH (posedge CLK1) (.400:.400:.400)) (WIDTH (negedge CLK1) (.400:.400:.400)) (PERIOD CLK1 (.909:1.111:1.429)) )